14.
Perform the necessary steps to prepare for tip calibration.
A.
Install a build sheet - make sure the build sheet is as centered as possible when placed onto
the platen.
B.
Verify vacuum - within about 5 minutes the printer should attain sufficient vacuum to secure
the build sheet to the platen. The red X over the top of the Vacuum Status Indicator will
disappear once sufficient vacuum is achieved (see
C.
Install canisters (see
filament to the drive wheels (see
five seconds after installation the printer reads the canister's memory chip and the canister's
information will be displayed within the Material Status Icons of the Dashboard.
Once finished, press the Next button to proceed with the wizard.
D.
"Canister Installation" on page
"Pre-load filament to the drive wheels" on page
"Information Bar" on page
120) and then pre-load the canister's
144
47).
122). About