8.10 Marking unit

8.10.1 Exchange of marking unit

The marking unit can can be exchanged by the following procedure:
3HAC051768-001 Revision: -
Disconnect the electrical contact by turning it anticlockwise
Unscrew the four M6 screws holding the marking unit
Replace with a new marking unit in reverse order.
CAUTION
If there are any changes in position/design between the new and old unit the
robot positions need to be updated.
CAUTION
Run system at slow speed for the first cycles to ensure the air cleaning box is
in correct position.