13 Appendix A: Configuration

13.2.5 Alarms

13.2.5 Alarms
Error codes are shown on the display in event of malfunctions. See the table below
for the most common error codes. Complete description of alarm/fault messages
are found in the frequency inverter manual.
The drive can be reset either by pressing the keypad key, RESET EXIT, or by
switching the supply voltage off for a while. When the fault has been removed, the
motor can be restarted.
Alarm messages
2001 Current limit
2002 Overvoltage
2003 Undervoltage
2009 High temp frequency inverter
Fault messages
0001 Current limit exceeded
0002 Over voltage
0003 High temperature frequency inverter
0004 Short-circuit in motorcables or motor
0006 Under voltage
0009 High motor temperature