A: In-conveyor points of interest, B: Out-conveyor points of interest, B
Location of belt tensioning screws
A: In-conveyor points of interest, B: Out-conveyor points of interest, B
3HAC051768-001 Revision: -
•
Open the belt splice by straightening the lock wire.
•
Connect the new belt to the old belt splice.
•
Drag the new belt with the help of the old belt through the FlexMT.
•
Remove old belt, then connect and lock the new belt splice.
•
Refit the idler drum below the middle of the conveyor.
•
Take special care to the belt path below the conveyor.
© Copyright 2014-2014 ABB. All rights reserved.
8 Repair
8.2.1 Exchange of conveyor belt
Continued
Continues on next page
167