8 Repair

8.4.2 Exchange of smart camera

8.4.2 Exchange of smart camera
Change of camera shall be performed with as little impact as possible on existing
teach-In. Use the following procedure:
CAUTION: Safely shut the power to the FlexMT down and lock against accidental
turn-on.
Location of smart camera mounting plate screws (view from below)
Location of smart camera mounting plate screws (view from side)
Continues on next page
172
Loosen the three cables connecting the smart camera
Loosen the four screws holding the camera mounting plate. Preferably use
a magnetic tool. See sketch below for identifying the location.
Remove camera from camera mounting plate and replace by new camera.
Move lens from the old smart camera to the new smart camera. Follow the
procedure for exchange of the camera lens.
Assemble camera mounting plate into FlexMT frame. Do not tighten screws
firmly yet.
Attach the three cables connecting the smart camera
Turn power to the FlexMT on.
Restore PickMT backup to the new smart camera