8.9.2 Exchange of valves

The valves controlling the deburring/grinding units are located below the statistic
outlet, next to the valves controlling the air cleaning nozzles. One or more valve
modules (Festo) can be exchanged by the following procedure:
Air cleaning box valve section cover
Bayonet fastenings holding the air cleaning box in place.
3HAC051768-001 Revision: -
Pull the statistic outlet to outer position.
Remove the protective cover over the valves (G).
Disconnect the pneumatic connections that connects the valves to FlexMT.
Disconnect the electrical connection to the distributor box.
Pull the two bayonet fastenings, placed in front of the air cleaning box, and
twist them 90°.
Drag the air cleaning box out of FlexMT.