ABB FlexMT Product Manual page 188

Table of Contents

Advertisement

8 Repair
8.9.2 Exchange of valves
Continued
Valve location for deburring units
188
Identify the valves (F) according to figure below.
Disconnect the pneumatic connections and the two M4 screws, placed
underneath, holding the valve.
Replace the valve with a new one.
Mount the air cleaning box in reverse order, make sure the air cleaning box
connects correct to the pins placed in the FlexMT frame.
CAUTION
If there are any changes in position/design between the new and old unit the
robot positions need to be updated.
CAUTION
Run system at slow speed for the first cycles to ensure the air cleaning box is
in correct position.