Appendix B: Communication; Inputs And Outputs; Conveyor System - ABB FlexMT Product Manual

Table of Contents

Advertisement

14 Appendix B: Communication

14.1 Inputs and outputs

14.1.1 Conveyor system

Name
diFeeder1InPosition
diFeeder1TooFar
diEmergencyStopOk
diFeeder1ManualForward
diFeeder1ManualBackward
diFeeder1SelectAutomatic
diOutFeeder1TooFar
diFeeder1SelectEmptying
diAlarmU11FeederIN
diAlarmU12FeederOUT
doRunForwardBelt1
doRunBackwardBelt1
doManualLampFeeder1
doRunFeederOut1
3HAC051768-001 Revision: -
Description
Sensor that indicates that parts are on the cameras field of
view
Sensor that indicates that parts are at the end of inconveyor
Emergency stop is not active
Knob for forward operation of inconveyor
Knob for backward operation of inconveyor
Knob for selecting method of operation (automatic – manual)
of inconveyor
Sensor that indicates that parts are at the end of outconveyor
Knob for selecting method of operation (automatic – empty-
ing) of outconveyor
Alarm from frequency inverter inconveyor
Alarm from frequency inverter outconveyor
Runs inconveyor forward
Runs inconveyor backward
Indication for operator when running inconveyor manually
is permitted
Run outconveyor
© Copyright 2014-2014 ABB. All rights reserved.
14 Appendix B: Communication
14.1.1 Conveyor system
225

Advertisement