The floor where the FlexMT becomes installed has to fulfill certain requirements:
26
•
Standard concrete industry floor is typically sufficient to install the FlexMT.
•
The surface of the floor shall be flat to within the equivalent of 1mm in 600mm
(1 inch in 50 ft).
•
The floor and fastening elements shall withstand the forces originating from
the robot according to the robot product manual. Use at least bolts with
minimum dimensions M20 / 3/4".