4.3.2 Functions for outconveyor
3HAC051768-001 Revision: -
•
Two operation positions, either automatic operation or emptying. Changing
operation mode via operator.
•
Sensor to stop the belt when the part reaches the end of the belt.
•
Time monitored belt stop with manual reset.
•
In order for outconveyor in emptying mode to start running after powering
up or emergency stop, a brief switch to automatic operation and back to
emptying mode is required.
© Copyright 2014-2014 ABB. All rights reserved.
4 Function description
4.3.2 Functions for outconveyor
89