4.3.2 Functions for outconveyor

3HAC051768-001 Revision: -
Two operation positions, either automatic operation or emptying. Changing
operation mode via operator.
Sensor to stop the belt when the part reaches the end of the belt.
Time monitored belt stop with manual reset.
In order for outconveyor in emptying mode to start running after powering
up or emergency stop, a brief switch to automatic operation and back to
emptying mode is required.