10
FUNCTIONS AND PROGRAMMING

10.2.6 Precautions for program debugging

(1) VxWorks image file specification
10
- 21
10.2 Programming Using Bus Interface Functions
10.2.6 Precautions for program debugging
To debug the user program, the same image file as that of VxWorks installed in the C
Controller module must be specified for Tornado.
(a) Specifying method
1) Make sure that the VxWorks image file in the system memory of the
development environment (personal computer) is matched with that of C
Controller module.
(
This section (1)(b))
2) Start Tornado.
3) Select [Tools]
"Configure Target Severs" dialog box.
4) Select "Core File and Symbols" in the "Target Server Properties" pull-down
menu.
5) Select the "File" radio button, and specify the VxWorks image file storage
location in the text box.
Specify a folder appropriate to the model when SW PVC-CCPU has been
installed into "C:\MELSEC". (
Model
Q06CCPU-V
C:\Melsec\CCPU\Vx\Tools\Q06CCPU-V_XXXXX-Y
Q06CCPU-V-B
C:\Melsec\CCPU\VxB\Tools\Q06CCPU-V-B_XXXXX-Y
The following screen provides an example of specifying the VxWorks image
file whose first five digits of serial No. are "09051" and whose function version
is "B".
[Target Server]
[Configure] from the menu bar to open the
This section (1)(b))
Table10.4 VxWorks image file storage location
Figure 10.6 VxWorks image file specification
File
4)
5)