9.4 MELSECNET/H Utility
9.4.6 Operating Parameter settings screen
Table9.80 Explanation of Parameter settings screen (Continued)
Target settings
Make the return setting of the control station.
This setting is available when "MNET/H mode (Control station)", "MNET/10 mode
(Control station)", or "MNET/H Ext. mode (Control station)" is selected for "Network
type".
(Initial value: "Return as control station", Setting range: "Return as control station",
"Return as normal station")
The network range is assigned.
This setting is available when "MNET/H mode (Control station)", "MNET/10 mode
(Control station)", or "MNET/H Ext. mode (Control station)" is selected for "Network type".
Set the total stations (including the control station) on the target network.
(Initial value: 2, Setting range: 2 to 64)
The device range input method can be switched between Points/Start and Start/End.
(Initial value: "Start/End")
Set the monitoring time for the link scan time. (Unit: 10ms)
(Initial value: 200, Setting range: 1 to 200)
Select the link device to which network range will be assigned.
"Low speed LB" and "Low speed LW" can be set when "MNET/H mode (Control station)"
or "MNET/H Ext. mode (Control station)" is selected for "Network type".
(Initial value: "LB/LW settings", Setting range: "LB/LW settings", "LX/LY settings (1)",
"LX/LY settings (2)")
Set the No. of the link device points assigned to the target station.
This setting is available when "Points/Start" is selected for "Assignment method".
(Initial value: "(Blank)", Setting range:
Set the start No. of the link device assigned to the target station.
(Initial value: "(Blank)", Setting range:
Set the end No. of the link device assigned to the target station.
This setting is available when "Start/End" is selected for "Assignment method".
(Initial value: "(Blank)", Setting range:
Sets the selected station as an I/O master station of the link device (LX/LY) or cancels
the setting.
This button can be used when "LX/LY settings (1)" or "LX/LY settings (2)"is selected for
"Switch screens".
Sets the selected station as a reserved station, or cancels the setting.
button
Displays the Equal assignment screen.(
Displays the Supplementary settings screen.(
Erases the "Points", "Start", and "End" settings and sets the initial values to "Total
stations" and "Monitoring time".
Description
This section (1)(a))
This section (1)(a))
This section (1)(a))
This section (4))
This section (5))