TROUBLESHOOTING
Index
Failed to save the event log file.
Failed to save the parameter file.
Confirm save location.
Failed to save the system information.
Failed to start up CC IE Control utility.
Failed to start up CC-Link utility.
Failed to start up Device monitoring utility.
[F]
Failed to start up MELSECNET/H utility.
Failed to write data to the buffer memory.
Failed to write parameters.
The probable causes are:
• The standard ROM does not have enough free space.
• The standard ROM has been shutdown.
• There is a problem in the hardware.
Failed to write the output data (Y).
Hour setting is out of range.
[H]
Set it within the range of 0 to 23.
I/O assignment comes after the base unit settings.
Set the number of slots.
I/O response time has not been set.
Set a value.
Intelligent function module parameters have not been set for the
specified project.
Interrupt event No. has not been set.
[I]
Set it within the range of 50 to 255.
Interrupt event No. is invalid.
Set it within the range of 50 to 255.
Interrupt event No. is out of range.
Set it within the range of 50 to 255.
IP address is out of range.
Check the address range and set it again.
Minute setting is out of range.
Set it within the range of 0 to 59.
Month setting is out of range.
[M]
Set it within the range of 1 to 12.
Multiple CPU parameters have not been set for the specified
project.
Table18.21 Error messages on C Controller setting utility (Continued)
Error message
Corrective action
Check the free space of the destination to save.
• Check the free space of the destination to save.
• Check the media of the destination to save.
• Set the total of the saving location and file names using 128
characters or less.
• Check the free space of the destination to save.
• Check the media of the destination to save.
Since installation of SW PVC-CCPU may have failed, reinstall
it.
Since installation of SW PVC-CCPU may have failed, reinstall
it.
Since installation of SW PVC-CCPU may have failed, reinstall
it.
Since installation of SW PVC-CCPU may have failed, reinstall
it.
• Check if an intelligent function module is mounted to the
specified slot.
• Check if the intelligent function module in the specified slot is
normal.
• Check if the C Controller module is operating normally.
• Increase the free space of the standard ROM, and write the
parameters again.
• Check if the standard ROM has been shut down (MODE LED
is flashing green). If it has been shut down, restart the C
Controller module, and then write the parameters again.
• Check the C Controller module for a hardware fault.
Check if the I/O assignment set by parameters is consistent with
the actual mounting status.
Enter a value within the range of 0 to 23.
Set the number of slots.
Set the I/O response time.
Check if any intelligent function module parameters have been
set in the specified project.
Enter the interrupt event within the range of 50 to 255.
Enter the interrupt event within the range of 50 to 255.
Enter the interrupt event within the range of 50 to 255.
Set the IP address within the allowable range.
Enter a value within the range of 0 to 59.
Enter a value within the range of 1 to 12.
Check the contents of the specified project file.
18.4 Error Code and Error Message Lists