Mitsubishi MELSEC-Q Series User Manual page 732

Hide thumbs Also See for MELSEC-Q Series:
Table of Contents

Advertisement

18
TROUBLESHOOTING
(2) Error codes returned by bus interface functions
Return value
(HEX)
0
Completed normally
-201
Module identification error
(0xFF37)
The specified module identification is invalid.
-202
Path error
(0xFF36)
The specified path is invalid.
-203
I/O No. error
(0xFF35)
The specified I/O No. is out of range.
-204
I/O access size error
(0xFF34)
The specified I/O access size is out of range.
-205
I/O No. error
(0xFF33)
The specified I/O No. is out of range.
-206
Program execution type error
(0xFF32)
The specified program execution type is out of range.
Offset error
-208
The specified offset is out of range.
(0xFF30)
AnS series module (buffer memory) was accessed.
Buffer memory size error
-209
The specified offset plus size is out of range.
(0xFF2F)
The address of data storage buffer pointer is 0.
-210
Read area size error
(0xFF2E)
The read area size is smaller than the read size.
-211
Time setting error
(0xFF2D)
Time setting is out of range.
-214
Intelligent function module error
(0xFF2A)
The intelligent function module is not mounted on the accessed slot.
-217
Driver not started
(0xFF27)
Driver has not been started.
-218
Bus already opened
(0xFF26)
"QBF_Open" is executed twice.
Program name error
-219
The specified program name is invalid (The program name does not
(0xFF25)
exist in the programmable controller CPU or is not registered with a
parameter).
-220
WDT type error
(0xFF24)
The specified WDT type is out of range.
18
- 51
18.4 Error Code and Error Message Lists
18.4.1 Actions by error codes generated at function execution
The following provides the error descriptions and corrective actions corresponding to
individual error codes returned when the bus interface functions are executed.
Refer to this section (1) for the common error codes returned by bus interface
functions and MELSEC data link functions.
Table18.9 Error codes returned by bus interface functions
Error description
* 1 In a single CPU configuration, reset the C Controller module.
In a multiple CPU configuration, reset CPU No.1.
Corrective action
Check the parameter.
Check the specified module.
Reboot the operating system.
Use the path pointer returned by "QBF_Open"
function.
Check the I/O No.
Check the I/O access size (I/O No. and read/
write size).
Check the I/O No.
Check the program execution type.
Check the offset.
Check the I/O No.
Check the specified buffer memory size.
Check the offset plus size.
Check the data storage buffer pointer.
Check the read size and read area size.
Check the specified time.
Check the I/O No.
Check if the intelligent function module is
mounted properly.
Check if the driver has been started.
Only one instance of "QBF_Open" can be
executed.
Check the program name.
Check the WDT type.
*1
(To next page)