Mitsubishi MELSEC-Q Series User Manual
Mitsubishi MELSEC-Q Series User Manual

Mitsubishi MELSEC-Q Series User Manual

Mes interface module
Hide thumbs Also See for MELSEC-Q Series:

Advertisement

MES Interface Module
Thank you for purchasing the Mitsubishi programmable controller
MELSEC-Q Series.
Prior to use, please read both this manual and detailed manual
thoroughly to fully understand the product.
© 2006 MITSUBISHI ELECTRIC CORPORATION
User's Manual
QJ71MES96
Model
QJ71MES96-U-HW
MODEL
CODE
IB(NA)-0800354-C(0809)MEE
(Hardware)
13JY02

Advertisement

Table of Contents
loading

Summary of Contents for Mitsubishi MELSEC-Q Series

  • Page 1 MES Interface Module User's Manual (Hardware) QJ71MES96 Thank you for purchasing the Mitsubishi programmable controller MELSEC-Q Series. Prior to use, please read both this manual and detailed manual thoroughly to fully understand the product. Model QJ71MES96-U-HW MODEL 13JY02 CODE IB(NA)-0800354-C(0809)MEE...
  • Page 2 SAFETY PRECAUTIONS (Always read these precautions before using this equipment.) Before using this product, please read this manual and the relevant manuals introduced in this manual carefully and pay full attention to safety to handle the product correctly. Note that these precautions apply only to this product. For the safety precautions of the programmable controller system, please read the User's Manual for the CPU module used.
  • Page 3 [Design Precautions] DANGER When controlling a running programmable controller (e.g. data modification), create an interlock circuit on sequence programs so that the whole system functions safely all the time. Also, be sure to read the manual carefully and ensure safety before performing any other controls such as operating status change.
  • Page 4 [Design Precautions] CAUTION Do not bunch the control wires or communication cables with the main circuit or power wires, or install them close to each other. They should be installed 100 mm (3.94 inch) or more from each other. Not doing so could result in noise that would cause erroneous operation. During registering each setting, do not power OFF the mounted module or reset the programmable controller CPU.
  • Page 5 [Installation Precautions] CAUTION Completely turn off the externally supplied power used in the system before mounting or removing the module. Not doing so could result in damage to the product. Tighten the screw in the specified torque range. Undertightening can cause a drop, short circuit or malfunction. Overtightening can cause a drop, short circuit or malfunction due to damage to the screw or module.
  • Page 6 [Wiring Precautions] CAUTION Tighten the screw in the specified torque range. Undertightening can cause a drop, short circuit or malfunction. Overtightening can cause a drop, short circuit or malfunction due to damage to the screw or module. When disconnecting communication cables connected to the module, never pull on the cable section.
  • Page 7 This manual confers no industrial property rights or any rights of any other kind, nor does it confer any patent licenses. Also, Mitsubishi Electric Corporation cannot be held responsible for any problems involving industrial property rights which may occur as a result of using the contents in this manual.
  • Page 8: Table Of Contents

    CONTENTS 1. OVERVIEW ....................1 2. PERFORAMNCE SPECIFICATIONS ............. 2 3. LOADING AND INSTALLATION ..............3 3.1 Handling Precautions ................3 3.2 Installation Environment ................3 4. PART NAMES ....................4 5. EXTERNAL WIRING ..................6 5.1 Connecting to the 10BASE-T/100BASE-TX ..........6 6.
  • Page 9 (1) For programmable controller system To configure a system meeting the requirements of the EMC and Low Voltage Directives when incorporating the Mitsubishi programmable controller (EMC and Low Voltage Directives compliant) into other machinery or equipment, refer to Chapter 9 "EMC AND LOW VOLTAGE DIRECTIVES"...
  • Page 10: Overview

    1. OVERVIEW This manual explains how to install the QJ71MES96 MES interface module (hereafter, abbreviated as MES interface module) and how to wire them with other devices. (Packing list) Model Product name Quantity QJ71MES96 MES interface module QJ71MES96 Battery (Q6BAT)
  • Page 11: Perforamnce Specifications

    2. PERFORAMNCE SPECIFICATIONS The following describes the performance specifications of the MES interface module. For general specifications of the MES interface module, refer to the following manual. QCPU User's Manual (Hardware Design, Maintenance and Inspection) Item Specifications Interface 10BASE-T 100BASE-TX Data transmission 10 Mbps...
  • Page 12: Loading And Installation

    3. LOADING AND INSTALLATION 3.1 Handling Precautions (1) Do not drop or apply severe shock to the module case since it is made of resin. (2) Before touching the module, always touch grounded metal, etc. to discharge static electricity from human body, etc. Not doing so can cause the module to fail or malfunction.
  • Page 13: Part Names

    4. PART NAMES (1) With the LED cover closed QJ71MES96 ERR. PULL CF CARD 10BASE-T/ 100BASE-TX QJ71MES96 (2) With the LED cover open PULL CF CARD 10BASE-T/ 100BASE-TX QJ71MES96...
  • Page 14 Name Description Indicator LED Refer to (3) Indicator LED display contents. Used for connecting the MES interface module in 10BASE-T/100BASE-TX 10BASE-T/100BASE-TX connection. interface connector (RJ45) (The MES interface module distinguishes 10BASE-T from 100BASE-TX depending on the device on other end.) Used for ejecting a CompactFlash card from the MES EJECT button interface module.
  • Page 15: External Wiring

    5. EXTERNAL WIRING 5.1 Connecting to the 10BASE-T/100BASE-TX When connecting to the 10BASE-T/100BASE-TX interface, use twisted pair cable. Use twisted pair cable that meets IEEE802.3 10BASE-T/100BASE-TX standards. (1) For 100 Mbps Either (a) or (b) of the following can be used. (a) Unshielded twisted pair cable (UTP cable), Category 5 (b) Shielded twisted pair cable (STP cable), Category 5 (2) For 10 Mbps...
  • Page 16: Setting From Gx Developer

    1: Does not detect battery errors. 1: Operates according to the default. User name :QJ71MES96 Password :MITSUBISHI Default operation setting [Network settings] 0: Operates according to [Network settings]. 1: Operates according to the default. IP ADDRESS :192.168.3.3 * When other than 0 is specified in this area, "Switch Subnet mask :255.255.255.0...
  • Page 17 (a) Default operation setting (bit 0, 1) Set whether to operate [Account setting] and [Network settings] with their default. 1) [Account setting] (bit 0) 0: Operates according to [Account setting]. 1: Operates according to the default. 2) [Network settings] (bit 1) 0: Operates accroding to [Network settings].
  • Page 18: External Dimensions

    7. EXTERNAL DIMENSIONS QJ71MES96 ERR. PULL CF CARD 10BASE-T/ 100BASE-TX (*1) QJ71MES96 90 (3.54) 27.4 (1.08) PULL CF CARD 10BASE-T/ 100BASE-TX QJ71MES96 (Unit: mm (inch)) The bending radius near the connector (R1: yardstick) should be at least four times longer than the cable's outside diameter when the twisted pair cable is connected.
  • Page 19: Transportation Precautions

    8. TRANSPORTATION PRECAUTIONS When transporting a battery containing lithium, handling according to transportation regulations is required. 8.1 Controlled Model The lithium battery used in the MES interface module is classified as follows. Classification for Product name Model Product supply status transportation Non-hazardous Q series battery...
  • Page 20 Warranty Mitsubishi will not be held liable for damage caused by factors found not to be the cause of Mitsubishi; machine damage or lost profits caused by faults in the Mitsubishi products; damage, secondary damage, accident compensation caused by special factors unpredictable by Mitsubishi;...