18
TROUBLESHOOTING
Index
Number of occupied stations has not been set for all of the
[N]
connected modules.
Set the number of occupied stations for each of the modules.
Only XX CC-Link modules are mounted.
Select XX or less and then execute monitoring.
[O]
Only XX CC-Link modules are mounted.
Select XX or less and then perform the test.
Parameter settings are not currently accessible.
Reading/writing parameters is being executed by another utility.
Please wait and try again.
[P]
Parameters for CC-Link module in slot XX has not been set.
Set parameters for the specified number of modules.
Please set any 8-point remote stations in pairs.
Receive buffer size is invalid.
Set it to 0 or within the range of 64 to 4096.
[R]
Retry count is invalid.
Set it within the range of 1 to 7.
Send buffer size is invalid.
Set it to 0 or within the range of 64 to 4096.
Setting all stations as "reserved station" is not allowed.
Change one of the stations to non-reserved station.
Start I./O No. has not been set.
Set it within the range of 0 to 0FE0.
Start I/O No. for slot XX and slot YY is overlapping.
Correct these settings.
[S]
Station No. is invalid.
Set it within the range of 0 to 63.
Station No. is invalid.
Set it within the range of 1 to 64.
Station type has not been set for all of the connected modules.
Set a station type for each of the modules.
Station type has not been set.
Set the station type.
Target CPU No. is invalid.
Set it within the range of 1 to 4.
The condition formula exceeds 2304.
Adjust setup such that the condition formula, ((16 X A) + (54 X B)
+ (88 X C)) <= 2304, is met. (A = number of I/O stations, B =
number of device stations, C = number of intelligent stations)
The maximum automatic buffer size is 4096.
Set it within the maximum automatic buffer size.
[T]
The maximum number of intelligent device stations is 26.
Set it within the maximum number of stations.
The maximum number of remote device stations is 42.
Set it within the maximum number of stations.
The maximum send/receive buffer size is 4096.
Set it within the maximum send/receive buffer size.
The maximum total number of occupied stations is 64.
Set it within the maximum number of occupied stations.
Table18.22 Error messages on CC-Link utility (Continued)
Error message
Corrective action
Set the occupied station count for the number of connected
modules set in the Station information settings.
Change the number of modules to be monitored to the number of
modules currently mounted and execute monitoring.
Change the number of test target modules to the number of
modules currently mounted or less and conduct the test.
Terminate the parameter reading/writing/verifying from another
utility (C Controller setting utility, CC-Link utility, MELSECNET/H
utility, or CC IE Control utility) and then reexecute.
Check if parameters have been set for the number of modules
set on the Parameter settings screen.
Set 8 points to each of remote stations in pair in the Station
information settings.
Set the receive buffer size in the Station information settings to 0
or within the range of 64 to 4096.
Set the Retry count in the Other settings within the range of 1 to
7.
Set the send buffer size in the Station information settings to 0 or
within the range of 64 to 4096.
Change one or more reserved station settings in the Station
information settings to "No setting" or "Invalid station".
Set the start I/O No. within the range of 0 to 0FE0.
Verify the start I/O No. of the mounted modules set on the
Parameter settings screen for duplicated numbers, and correct
the setting if any duplication is found.
Set a station No. within the range of 0 to 63.
Set a target station No. of line test within the range of 1 to 64.
Set station types for the number of connected modules set in the
Station information settings.
Set a station type.
Set the target CPU No. within the range of 1 to 4.
Make setting so that the station type data in the Station
information settings satisfies the conditional expression {(16XA)
+ (54XB) + (88XC) } <= 2304 (A: No. of I/O stations, B: No. of
device stations, C: No. of intelligent stations).
Adjust the auto buffer size total in the Station information settings
to 4096 or less.
In the Station information settings, adjust the number of
intelligent device stations to 26 or less.
Adjust the number of remote device stations in the Station
information settings to 42 or less.
Adjust the send/receive buffer size total in the Station information
settings to 4096 or less.
Adjust the total occupied station count for the number of
connected modules set in the Station information settings to 64
or less.
18.4 Error Code and Error Message Lists
18.4.3 Actions by error messages
17
18
(To next page)
18
- 72