9
UTILITY OPERATION
Parameter settings
Online operation
Item
Number of modules
*1
Link device refresh cycle
button
Routing parameter
Target module
Start I/O No.
Channel No.
button
Refresh parameters
button
Check
button
Default
Operation settings
Network No.
Group No.
Mode
Network type
Table9.80 Explanation of Parameter settings screen
Target settings
Set the number of MELSECNET/H modules to be controlled by the C Controller module.
Selecting "(Blank)" is recognized as no setting (Setting clear).
(Initial value: "(Blank)", Setting range: 1 to 4, "(Blank)")
Set the refresh cycle of the link device. (Unit: ms) (
When using both the CC-Link IE controller network and MELSECNET/H, set the same
value as the one set in the CC IE Control utility.
(Initial value: 100, Setting range: 0
Displays the Routing parameter settings screen.(
Select the module for which parameters are set. (Initial value: 1, Setting range: 1 to 4)
Refer to the following for details of the number assigned to this item.
Section 9.3.5 (1)(a)
Set the start I/O No. of the MELSECNET/H module.
(Setting range: 0 to FE0
(Note that duplication with the start I/O No. set to another
H
MELSECNET/H module is not allowed.))
Set the channel No. of the MELSECNET/H module.
Use the value set here when opening the channel from the Device monitoring utility or
user program (MELSEC data link function). (Q06CCPU-V only)
(Setting range: 51 to 54 (Note that duplication with the channel No. set to another
MELSECNET/H module is not allowed.))
Displays the Refresh parameter settings screen.(
Checks for any setting error.
Sets the operation settings, network range assignments, and refresh parameters to
initial values.
Specify the MELSECNET/H module operation.
Set the network No. of the MELSECNET/H module.
(Initial value: 1, Setting range: 1 to 239)
Set the group No. of the MELSECNET/H module.
(Initial value: 0, Setting range: 0 to 32)
Set the mode of the MELSECNET/H module.
(Initial value: "Online", Setting range: "Online", "Offline", "F. loop test", "R. loop test",
"Sta. to sta. test (performs test)", "Sta. to sta. test (being tested)")
Set the type of the MELSECNET/H module.
(Initial value: "MNET/H mode (Control station)", Setting range: "MNET/H mode (Control
station)", "MNET/H mode (Normal station)", "MNET/10 mode (Control station)", "MNET/
10 mode (Normal station)", "MNET/H Ext. mode (Control station)", "MNET/H Ext. mode
(Normal station)")
* 1 For the block data assurance per station (
device refresh cycle, and configure refresh parameters.
* 2 When 0 is set to the link device refresh cycle, refresh is not performed with all refresh parameter
settings deleted, and the
Refresh parameters
Description
*2
, 10 to 1000)
This section (2))
This section (3))
This section (5)), set 10 or higher for the link
button does not function.
9.4 MELSECNET/H Utility
9.4.6 Operating Parameter settings screen
Section 4.4.4)
(To next page)
9
- 120
9
10
11
12
13
14
15
16