TROUBLESHOOTING
Index
OCT input range error.
[O]
Enter 0 to 7.
[P]
Points data have not been entered.
Setting data have not been entered.
[S]
Station No. has not been entered.
Station No. is out of range.
The number of points is out of range.
The specified connection target was not found in the
communication test.
Check the following things and run the communication test
again.
• Check the power supply, cables, and network settings.
[T]
• Check if the computer is still booting.
There is no device that can be used with this function.
This function is not supported by the connected C Controller
module.
Check the model name or version of the C Controller module.
Unable to communicate with XX:YY.
*1
Error code : ZZ
(DEC with signs)
[U]
Unable to communicate with XX:YY.
*2
Error code : ZZ
(DEC with signs)
Unable to find information required for utility start-up.
Please reinstall.
18
- 87
18.4 Error Code and Error Message Lists
18.4.3 Actions by error messages
Table18.25 Error messages on Device monitoring utility (Continued)
Error message
* 1 ZZ is other than -300 to -399.
* 2 ZZ is -300 to -399.
Corrective action
Enter an octal number of 0 to 7.
Enter the number of points.
Enter the setting data.
Enter a station No.
Check the allowable station No. range and enter a station No.
Check the setting point range before entering points.
Conduct a communication test after checking the following.
• Check if the target C Controller module is operating.
• Check if the Ethernet cable is connected.
• Check if the specified IP address or host name is correct.
• Check that the development environment (personal computer)
is not starting up.
• Check for bi-directional connection with another personal
computer (with the PING command, etc.) to see if the
development environment (personal computer) is connected
to the network.
• Check that Windows
Firewall is disabled.
R
Select a device available for this function and use it.
Check the model name or version of the specified C Controller
module.
Error list of MELSEC data link function HELP
Since a timeout has occurred in communication with the target,
retry (e.g. Start monitoring, Device settings) after checking the
following.
• Check if the target C Controller module is operating.
• Check if the Ethernet cable is connected.
• Check if the specified IP address or host name is correct.
• Using the C Controller setting utility, set the priority setting of
the utility communication task to a smaller value or default.
(
Section 9.2.6 (2)(d))
• Check the line state.
If the line is congested, a communication error (timeout error)
tends to occur (monitoring tends to stop).
• Check the monitor performance state.
If other station access (e.g. access via CC-Link module and
MELSECNET/H module) is frequently performed, a
communication error (timeout error) tends to occur.
Since installation of SW PVC-CCPU may have failed, reinstall
it.