Serial port
l
l
rs-422
n
l
rs-485
n
l
l
The default is rs-232.
7. (Optional) Set a label that will be used when referring to this port.
(config)>path-paramlabel label
(config)>
8. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
9. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Configure RealPort mode

You can configure the Connect EZ to communicate with your computer using RealPort.
Note
If you are using the Windows OS, you can also enable and configure RealPort mode for the
Connect EZ device and your computer from the Digi Navigator. See
Step 1: Install Realport
You can install RealPort on a computer with either a Windows OS or a Linux OS.
Digi Connect EZ Mini User Guide
For rts_pre_delay, enter the amount of time RTS is asserted before starting data
transmission. The time is measured in milliseconds. The default is 0ms:
(config)> serial port1 "rts_pre_delay value
(config)>
For rts_post_delay, enter the amount of time RTS is deasserted before completing
data transmission. The time is measured in milliseconds. The default is 0ms:
(config)> serial port1 rts_post_delay value
(config)>
Enable Termination if you want to enable electrical termination on this serial port.
Enable termination if you want to enable electrical termination on this serial port:
(config)> serial port1 termination true
(config)>
Enable full_duplex if you want to enable full duplex communication on this serial
port:
(config)> serial port1 full_duplex true
(config)>
Configure RealPort mode
Digi Navigator
application.