Services
d. Click  again to allow access through additional firewall zones.
5. Click Apply to save the configuration and apply the change.
  Command line
1. Log into the Connect EZ command line as a user with full Admin access rights.
Depending on your device configuration, you may be presented with an Access selection
menu. Type admin to access the Admin CLI.
2. At the command line, type config to enter configuration mode:
> config
(config)>
3. Enable the iPerf server:
(config)> service iperf enable true
(config)>
4. (Optional) Set the port number for the iPerf server listening port. The default is 5201.
(config)> service iperf port port_number
(config)>
5. (Optional) Set the access control list to restrict access to the iPerf server:
To limit access to specified IPv4 addresses and networks:
n
(config)> add service iperf acl address end value
(config)>
Where value can be:
A single IP address or host name.
l
A network designation in CIDR notation, for example, 192.168.1.0/24.
l
any: No limit to IPv4 addresses that can access the service-type.
l
Repeat this step to list additional IP addresses or networks.
To limit access to specified IPv6 addresses and networks:
n
(config)> add service iperf acl address6 end value
(config)>
Where value can be:
A single IP address or host name.
l
A network designation in CIDR notation, for example, 2001:db8::/48.
l
any: No limit to IPv6 addresses that can access the service-type.
l
Repeat this step to list additional IP addresses or networks.