Regeneration operation procedure
1.
Stop the vehicle, put the parking brake on
and remove the ignition switch.
2.
Insert the plug into an external power
supply connection socket and turn it in
the locking direction.
3.
Press the regeneration switch on the dis-
play. The buzzer rings to start regenera-
tion.
Caution
Caution
Remove your finger once the buzzer
rings and the regeneration indicator
lamp comes on. Pressing the switch for a
long time stops regeneration operation
procedure.
With the ignition switch ON, the power
will not come on even if you press the
regeneration switch.
If the external power is supplied, with
the ignition switch ON, the buzzer will
sound.
Always use your fingertip to operate the
switch panel on the display.
If the regeneration indicator lamp
should come on without the buzzer
sounding, ask a Toyota dealer for an
inspection.
4.
When regeneration starts, the regenera-
tion indicator lamp and the trapping indi-
cator lamps (all six) come on.
Note:
The microcomputer (ECU) automatically car-
ries out regeneration, so the operator does not
have to attend to the vehicle.
(2)
(1)
(1) Unlock
(2) Remove
5.
The trapping indicator lamps go out in
sequence from right to left (yellow →
green) as regeneration proceeds. (every
10 minutes)
6.
Once regeneration is over, all the indica-
tor lamps go out and regeneration auto-
matically stops.
Note:
The regeneration time is about 50 minutes
when the green trapping indicator lamps (up to
5) light and about 70 minutes when the yellow
trapping indicator lamp lights.
7.
Be sure to remove the power plug.
Caution
Caution
Soot combustion interruption (Regenera-
tion interruption)
When interruption soot combustion in
progress is unavoidable, press the regenera-
tion switch for about 5 seconds until the
buzzer sounds. Then, the left green lamp
and the regeneration indicator lamp will
come on. After about 5 minutes, when all
the indicator lamps are off, the engine can
be activated again. Plug out the power cable
after the regeneration indicator lamp is off.
Do not interrupt soot combustion unless
unavoidable as next soot combustion will be
required earlier due to combustion remains.