Hour Meter/Control Module Installation

1. Install the hour meter in through the control panel.
Ensure that the mounting clips have secured the
switch in the control panel (Fig. 860).
Fig. 860
Note: The hour meter must be orientated so it can
be read from the front of the machine (Fig.
861).
Fig. 861
36" & 40" Toro GrandStand Service Manual
2. Install the wire harness to the back of the hour meter
(Fig. 862).
DSCN-2333a
DSCN-2338a
ELECTRICAL
Fig. 862
DSCN-2328a
8