HYDRAULIC DRIVE SYSTEM
4. Install the inlet fitting into the filter mount inlet port
(Fig. 528).
Note: Do not tighten the jam nut at this time.
5. Secure the suction hose to the inlet fitting, then
secure the position of the fitting with the jam nut (Fig.
529).
6
6-30
Fig. 528
DSCN-2916a
Fig. 529
DSCN-2913a
6. Apply a thin coat of hydraulic fluid to the rubber
gasket on the replacement filter (Fig. 530).
Fig. 530
7. Install the replacement filter to the filter mount (Fig.
531).
Fig. 531