Pneumatic Pass-Through Connections; Robot Solenoid Option Consideration For Ip65 Robots - Omron eCobra 600 User Manual

With ethercat
Hide thumbs Also See for eCobra 600:
Table of Contents

Advertisement

Key
A
B
C

Pneumatic Pass-through Connections

The user air line connectors have removable plugs fitted at the factory. Refer to User Con-
nectors on eCobra Robot on page 162.
The pass-through connectors on the outer link are accessible with the cover removed. See Fig-
ure 9-13. for locations of the internal connectors.
When routing air lines outside of the robot, any fittings you use must maintain an adequate
seal in the cover to prevent moisture from entering the outer link.
!

Robot Solenoid Option Consideration for IP65 Robots

If you are installing the internally-mounted solenoid valves on a robot with the IP65 option,
you must use a different air line than what is described in Installing the Solenoid Valve Kit on
page 89.
The internal air line normally used to supply the solenoid manifold is instead used to provide
positive airflow pressure to the bellows / outer link. You can use one of the passive 6 mm user
air lines shown in Figure 9-12. and Figure 9-13.
24402-000 Rev B
Figure 9-13. IP65 Internal Connectors with Outer Link Cover Removed
Meaning
6 mm Air Lines
User Electric
4 mm Air Line
CAUTION: PROPERTY DAMAGE RISK
Failure to prevent water intrusion through improperly-sealed external fittings
could void your warranty.
eCobra 600 and 800 Robots with EtherCAT
Chapter 9: IP65 Option Considerations
Key
D
DeviceNet
E
4 mm Air Line
F
Two spare Air Lines
Meaning
163