1. Remove the red shipping plug from the compressed air fitting on the top of the robot.
Figure 9-3. Compressed Air Inlet Port - 3/8 inch NPT Female fitting (A) and Hugh Flow-Low Vacuum
2. Connect a compressed air source to the air fitting. The specification for the regulated air
supply is shown in the following table.
!
24402-000 Rev B
Port - 3/4 Inch NPT Female Fitting (B)
Table 9-1. Compressed Air Specifications
Required Air Pressure
3 bar, ±10%
(44 PSI, ±10%)
CAUTION: PROPERTY DAMAGE RISK
The compressed air supply must be clean and dry and it must be turned on
continuously to maintain a positive air pressure inside the robot. Failure to do
this could result in moisture or particle buildup inside the robot, lead to
reduced performance or damage to the robot, and could void your warranty.
eCobra 600 and 800 Robots with EtherCAT
Chapter 9: IP65 Option Considerations
Required Air Flow, Minimum
57 liters per minute
(2 cubic feet per minute)