Sealing The Tool Flange; Pressurizing The Robot - Omron eCobra 600 User Manual

With ethercat
Hide thumbs Also See for eCobra 600:
Table of Contents

Advertisement

IMPORTANT: These two requirements of sealing the tool flange and pres-
surizing the robot are critical to achieving the IP65 level of protection.
As part of a your periodic maintenance plan, inspect the robot periodically to make sure these
requirements are being met.

Sealing the Tool Flange

The tool flange must be sealed so that the robot shell can be positively pressurized. The pos-
itive pressure reinforces the sealing properties of the gaskets and seals provided in the IP65
robot.
The tool flange for the IP65 robot has an additional protective shield on the outer edge that is
not present on the standard robot tool flange. Refer to the following figure for the side view
dimensions. The bottom face of the flange (mounting surface) is the same as the standard
flange, so the dimensions in Robot Physical Dimension Drawings on page 131 are the same.

Pressurizing the Robot

You must supply compressed air to keep a positive airflow pressure in the robot cavity.
154
3.8
Figure 9-2. eCobra 800 IP65 Tool Flange (units in mm)
eCobra 600 and 800 Robots with EtherCAT
20.0
12.0
41.15
76.2
72.2
6.8
24402-000 Rev B

Advertisement