Goodrive300-19 series open loop vector inverter special for hosit
Frequency resolution
Current
Power limit
Field weakening
point
Carrier frequency
A.4.1 EMC compatibility and motor cable length
To comply with the European EMC Directive (2004/108/EC), use the following maximum motor cable
lengths for 4kHz switching frequency.
All frame sizes (with external EMC filter)
Second environment (category C3)
First environment (category C2)
The maximum motor cable length is determined by the drive's operational factors. Contact the local
representative for the exact maximum lengths when using external EMC filters.
For the instruction of the second environment (category C3) and first environment (category C2),
please refer to EMC regulations.
A.5 Applicable standards
The inverter complies with the following standards:
EN/ISO 13849-1:2008
IEC/EN 60204-1:2006
IEC/EN 62061:2005
IEC/EN 61800-3:2004
IEC/EN 61800-5-1:2007
IEC/EN 61800-5-2:2007
A.5.1 CE marking
The CE mark is attached to the drive to verify that the drive follows the provisions of the European
Low Voltage and EMC Directives.
0.01Hz
Refer to Ratings
1.5· PN
10...400Hz
4, 8, 12 or 15kHz
Safety of machinery-Safety related parts of control systems. Part
1: General principles for design
Safety of machinery. Electrical equipment of machines. Part 1:
General requirements
Safety of machinery–Functional safety of safety-Related
electrical, electronic and programmable electronic control
systems
Adjustable speed electrical power drive systems. Part 3: EMC
requirements and specific test methods
Adjustable speed electrical power drive systems–Part 5-1:
Safety requirements–Electrical, thermal and energy
Adjustable speed electrical power drive systems–Part 5-2:
Safety requirements–Functional
-231-
Maximum motor cable length (m)
30
30
Technical data