Hierarchical Multi-Step Speed Running - INVT Goodrive300-19 Series Operation Manual

Open loop vector inverter special for hoist
Table of Contents

Advertisement

Goodrive300-19 series open loop vector inverter special for hosit

7.15 Hierarchical multi-step speed running

Hierarchical multi-step speed reference is a speed reference mode specially designed according to
the applications of hoists. The mode can realize at most 6 steps hierarchical speed selection through
the combinations of 5 hierarchical speed reference terminals, as shown below:
Hierarchical
Hierarchical
reference
reference
terminal 1
terminal 2
OFF
OFF
ON
OFF
ON
ON
ON
ON
ON
ON
ON
ON
Note: Only when all lower hierarchical references close can the upper hierarchical references
close. Generally, set hierarchical reference 0 to 0.0%.
Set speed reference to hierarchical multi-step speed reference mode (P00.06=13 or P00.07=13). The
hierarchical terminal reference is determined by the combinations of 61-65 in P5 group and the speed
is set by P19.06~P19.11 (the percentage of P00.03).
Function
code
P00.06
A frequency command
P00.07
B frequency command
P05.00
HDI input selection
P05.01
S1 terminal function selection 61: Hierarchical reference terminal 1
P05.02
S2 terminal function selection
P05.03
S3 terminal function selection
P05.04
S4 terminal function selection
P05.05
S5 terminal function selection
Hierarchical
Hierarchical
reference
reference
terminal 3
terminal 4
OFF
OFF
OFF
ON
ON
ON
Name
13: Hierarchical multi-step speed
reference
0: High-speed pulse input
1: Digital input
62: Hierarchical reference terminal 2
63: Hierarchical reference terminal 3
64: Hierarchical reference terminal 4
65: Hierarchical reference terminal 5
Hierarchical
reference
terminal 5
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
OFF
ON
ON
Detailed instruction of parameters
-180-
Basic operation instruction
Speed
Function
setting
code
Hierarchical
P19.06
reference 0
Hierarchical
P19.07
reference 1
Hierarchical
P19.08
reference 2
Hierarchical
P19.09
reference 3
Hierarchical
P19.10
reference 4
Hierarchical
P19.11
reference 5
Default
value
0
2
0
1
2
7
0
0

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive300-19 Series and is the answer not in the manual?

Questions and answers

Table of Contents