Goodrive300-19 series open loop vector inverter special for hosit
Function
Name
code
B frequency
P00.08
command
reference
Combination
P00.09
of setting
source
P00.10
Keypad set When A and B frequency commands are selected as
Detailed instruction of parameters
P00.06 or P00.07 equals to 6.
7: Reserved
8: Modbus communication setting
The frequency is set by Modbus communication. See
P14 for detailed information.
9~12: Reserved
13: Hierarchical multi-step speed reference
The inverter runs at hierarchical multi-step speed
mode when P00.06=13 or P00.07=13. Set P05 to
select the current running stage, and set P19 to select
the current running frequency.
0: Maximum output frequency, 100% of B frequency
setting corresponds to the maximum output
frequency
1: A frequency command, 100% of B frequency
setting corresponds to the maximum output
frequency. Select this setting if it needs to adjust on
the base of A frequency command.
0: A, the current frequency setting is A frequency
command
1: B, the current frequency setting is B frequency
command
2: A+B, the current frequency setting is A frequency
command + B frequency command
3: A-B, the current frequency setting is A frequency
command - B frequency command
4: Max (A, B): The bigger one between A frequency
command and B frequency is the set frequency.
5: Min (A, B): The lower one between A frequency
command and B frequency is the set frequency.
Note: The combination manner can be shifted by
P5 (terminal function)
-47-
Function parameters
Default
Modify
value
0
0
50.00Hz