INVT Goodrive300-19 Series Operation Manual page 177

Open loop vector inverter special for hoist
Table of Contents

Advertisement

Goodrive300-19 series open loop vector inverter special for hosit
Function
Name
code
Previous fault
P07.28
type
Previous 2
P07.29
fault type
Detailed instruction of parameters
14: Output side phase loss (SPO)
15: Overheat of the rectifier module (OH1)
16: Overheat fault of the converter module (OH2)
17: External fault (EF)
18: 485 communication fault (CE)
19: Current detection fault (ItE)
20: Motor antotuning fault (tE)
21: EEPROM operation fault (EEP)
22: Reserved
23: Braking unit fault (bCE)
24: Running time arrival (END)
25: Electrical overload (OL3)
26: Panel communication fault (PCE)
27: Parameter uploading fault (UPE)
28: Parameter downloading fault (DNE)
29~31: Reserved
32: Grounding short circuit fault 1 (ETH1)
33: Grounding short circuit fault 2 (ETH2)
34: Speed deviation fault (dEu)
35: Maladjustment (STo)
36: Underload fault (LL)
37~38: Reserved
39: Inverter enabling fault (dIS)
40: Contactor feedback fault (TbE)
41: Brake feedback fault (FAE)
42: Torque verification fault (TPF)
43: Joystick zero fault (STC)
44: Hierarchical reference fault (STEP)
45: Analog speed reference deviation fault (AdE)
-176-