Goodrive300-19 series open loop vector inverter special for hosit
Function
Name
code
asynchronous
motor 1
Rated speed
of
P02.03
asynchronous
motor 1
Rated voltage
of
P02.04
asynchronous
motor 1
Rated current
of
P02.05
asynchronous
motor 1
Multi-function
P05.01~
digital input
P05.09
terminal
Parameter
P07.01
copy
QUICK/JOG
P07.02
function
selection
Detailed instruction of parameters
1~36000rpm
0~1200V
0.8~6000.0A
36: Shift the command to the keypad
37: Shift the command to the terminal
38: Shift the command to the communication
The function code determines the manner of parameters
copy.
0: No operation
1: Upload the local function parameter to the keypad
2: Download the keypad function parameter to local
address (including the motor parameters)
3: Download the keypad function parameter to local
address (excluding the motor parameter of P02 and P12
group)
4: Download the keypad function parameters to local
address (only for the motor parameter of P02 and P12
group)
0: No function
1: Jogging
2: Shift the display state by the shifting key
3: Shift between forward rotations and reverse rotations
-120-
Basic operation instruction
Default
value
Depend
on model
Depend
on model
Depend
on model
0
1
Need help?
Do you have a question about the Goodrive300-19 Series and is the answer not in the manual?