Goodrive300-19 series open loop vector inverter special for hosit
Function
Name
code
Shifting
between
P01.14
FWD/REV
rotation
Stopping
P01.15
speed
Detection of
P01.16
stopping
speed
Detection
time of
P01.17
feedback
speed
Detailed instruction of parameters
Setting range: 0.0~3600.0s
Set the threshold point of the inverter:
0: Switch after zero frequency
1: Switch after the starting frequency
2: Switch after the speed reaches P01.15 and delays
for P01.24
0.00~100.00Hz
0: Detect according to speed setting (no stopping
delay)
1: Detect according to speed feedback (only valid for
vector control)
If set P01.16 to 1, the feedback frequency is less than
or equal to P01.15 and detect in the set time of
P01.17, the inverter will stop; otherwise, the inverter
will stop after the set time of P01.17.
Setting range: 0.00~100.00s (only valid when
P01.16=1)
-54-
Function parameters
Default
Modify
value
◎
2
◎
0.50Hz
◎
1
◎
0. 50s