INVT Goodrive300-19 Series Operation Manual page 53

Open loop vector inverter special for hoist
Table of Contents

Advertisement

Goodrive300-19 series open loop vector inverter special for hosit
Function
Name
code
starting
ACC/DEC
P01.05
selection
S curve
P01.06
start
proportion
S curve end
P01.07
proportion
P01.08
Stop mode
Detailed instruction of parameters
means the percentage of the rated current of the
inverter.
The setting range of P01.03: 0.0~100.0%
The setting range of P01.04: 0.00~50.00s
The changing mode of the frequency during start-up
and running.
0: Linear type
The output frequency increases or decreases linearly.
1: S curve type
The output frequency increases or decreases in S
curve.
S curve is suitable in the cases that require smooth
start-up and stop, such as elevators and conveyors.
0.0~50.0% (ACC/DEC time)
0.0~50.0% (ACC/DEC time)
0: Decelerate to stop: after the stop command
becomes valid, the inverter decelerates to decrease
the output frequency during the set time. When the
-52-
Function parameters
Default
Modify
value
0
30.0%
30.0%
0