INVT Goodrive300-19 Series Operation Manual page 185

Open loop vector inverter special for hoist
Table of Contents

Advertisement

Goodrive300-19 series open loop vector inverter special for hosit
Function
code
Brake and contactor control
P19.01
7.16.3 Remote control mode
The wiring diagram of remote control mode is as follows:
Frequency reference
The mode is used in the case where the joystick is connected to the external wireless controller or
PLC. Set P19.00 to "2: Remote control mode".
The speed is given by AI1 and the forward and reverse direction signals of the hoist are given by S1
and S2. For remote control mode, joystick zero position detection is invalid.
The parameters of remote control mode are as follows:
Function
code
P00.01
Running command channel
P00.06
A frequency command
P05.01
S1 terminal function selection
P05.02
S2 terminal function selection
P05.03
S3 terminal function selection
P06.03
P06.04
P06.07
P06.08
P19.01
Brake and contactor control
Name
selection
GD300-19 inverter
AI1
FWD running
S1
REV running
S2
Fault reset
S3
Name
Relay RO1 output
Relay RO2 output
AO1 output
AO2 output
Function
selection
0x01
Brake is controlled by inverter
RO1
RO2
Running frequency
AO1
AO2
Function
selection
Terminal
1
channel (LED flickering)
1
AI1 setting
1
Forward rotation operation (FWD)
2
Reverse rotation operation (REV)
7
Fault reset (RET)
5
Fault output
34
Brake control output
0
Running frequency
5
Current output
0x01
Brake is controlled by inverter
-184-
Basic operation instruction
Function instruction
Fault output
Brake output
Current output
Function instruction
running
command

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive300-19 Series and is the answer not in the manual?

Questions and answers