Goodrive300-19 series open loop vector inverter special for hosit
Function
Name
code
Cooling fan
P08.39
running
mode
PWM
P08.40
selection
Over
P08.41
commission
selection
Keypad
P08.42
data control
Detailed instruction of parameters
voltage
380V
range
685~750
V
0: Normal mode
1: The fan keeps running after power on
0x00~0x21
LED ones: PWM mode selection
0: PWM mode 1, three-phase modulation and
two-phase modulation
1: PWM mode 2, three-phase modulation
LED tens: low-speed carrier frequency limit mode
0: Low-speed carrier frequency limit mode 1, the
carrier frequency will limit to 2k if it exceeds 2k at low
speed
1: Low-speed carrier frequency limit mode 2, the
carrier frequency will limit to 4k if it exceeds 4k at low
speed
2: No limit
0x00~0x11
LED ones
0: Invalid
1: Valid
LED tens (for factory commissioning)
0: Light overcommission; in zone 1
1: Heavy overcommission; in zone 2
0x000~0x1223
LED ones: frequency enable selection
0: Both ∧/∨ key and digital potentiometer
adjustment are valid
1: Only ∧/∨ key adjustment is valid
2: Only digital potentiometer adjustment is valid
3: Neither ∧/∨ key nor digital potentiometer
500V
860~950V
1080~11
-95-
Function parameters
Default
value
660
690V
voltage:
1120.0V
80V
0
01
00~11
0x0000
Modify
○
◎
01
○
Need help?
Do you have a question about the Goodrive300-19 Series and is the answer not in the manual?
Questions and answers