Goodrive300-19 series open loop vector inverter special for hosit
command
channel
Motor
P00.15
parameter
autotuning
Rated power
of
P02.01
asynchronous
motor 1
Rated
frequency of
P02.02
asynchronous
motor 1
Rated speed
of
P02.03
asynchronous
motor 1
Rated voltage
of
P02.04
asynchronous
motor 1
Rated current
of
P02.05
asynchronous
motor 1
Stator resistor
of
P02.06
asynchronous
motor 1
Rotor resistor
of
P02.07
asynchronous
motor 1
P02.08
Leakage
1: Terminal running command channel (LED flickering)
2: Communication running command channel (LED on)
0: No operation
1: Rotation autotuning
2: Static autotuning 1 (autotune totally)
3: Static autotuning 2 (autotune partially)
0.1~3000.0kW
0.01Hz~P00.03
(the Max. frequency)
1~36000rpm
0~1200V
0.8~6000.0A
0.001~65.535Ω
0.001~65.535Ω
0.1~6553.5mH
-140-
Basic operation instruction
0
Depend
on model
50.00Hz
Depend
on model
Depend
on model
Depend
on model
Depend
on model
Depend
on model
Depend