8.6.2 Motor vibration
No
Set right V/F vibration
parameter or not
Set right parameter
No
Yes
Motor vibration or
abnormal noise
Check the motor parameter
or motor type is right or not
Yes
Perform parameter
autotune or not
Yes
Vector control or not
Yes
Check the speed loop and
current loop are right or not
Yes
Check if there is abnormal
vibration to frequency
reference
No
Check if there is abnormal
fluctuation to the load
No
If it is the inverter fault,
please contact with our
company
-197-
Fault tracking
Please set right
No
motor type and
parameters
No
Perform right
parameter autotune
No
Set right
parameters
Yes
Check frequency
reference
Yes
Check the load

Hide quick links: