Goodrive300-19 series open loop vector inverter special for hosit
FWD/REV
rotation
Stopping
P01.15
speed
Detection of
P01.16
stopping
speed
Terminal
running
P01.18
protection
when
powering on
Action if
running
frequency<
P01.19
lower limit
frequency
(valid>0)
Hibernation
P01.20
restore delay
time
Restart after
P01.21
power off
The waiting
time of restart
P01.22
after power
off
Start delay
P01.23
time
Delay time of
P01.24
stop speed
Multi-function
P05.01~
digital input
P05.09
terminal
2: Switch after the speed reaches P01.15 and delays for
P01.24
0.00~100.00Hz
0: Detect according to speed setting (no stopping delay)
1: Detect according to speed feedback (only valid for
vector control)
0: The terminal running command is invalid when powering
on.
1: The terminal running command is valid when powering
on.
0: Run at the lower-limit frequency
1: Stop
2: Hibernation
0.0~3600.0s (valid when P01.19=2)
0: Disable
1: Enable
0.0~3600.0s (valid when P01.21=1)
0.0~60.0s
0.0~100.0s
1: Forward rotation operation
2: Reverse rotation operation
4: Forward jogging
5: Reverse jogging
-146-
Basic operation instruction
0.50Hz
1
0
0
0.0s
0
1.0s
0.0s
0.0s