INVT Goodrive300-19 Series Operation Manual page 70

Open loop vector inverter special for hoist
Table of Contents

Advertisement

Goodrive300-19 series open loop vector inverter special for hosit
Function
Name
code
frequency of
motor 2
Vibration
control factor
P04.24
at high
frequency of
motor 2
Vibration
control
P04.25
threshold of
motor 2
Energy-
P04.26
saving
operation
Voltage
P04.27
setting
Keypad
P04.28
setting
voltage
P04.29
Voltage
Detailed instruction of parameters
overcurrent may occur. These phenomena can be
canceled by adjusting this parameter.
The setting range of P04.23: 0~100
The setting range of P04.24: 0~100
The setting range of P04.25: 0.00Hz~P00.03 (the
Max. frequency)
0: No operation
1: Automatic energy-saving operation
Motors will automatically adjust the output voltage to
save energy at light loads.
Select the output setting channel at V/F curve
separation.
0: Keypad: the output voltage is determined by
P04.28.
1: AI1
2: AI2
3: AI3
4: HDI
5: Multi-step speed
6: Reserved
7: Modbus communication
8~10: Reserved
Note: 100% corresponds to the rated voltage of
the motor.
The function code is the voltage displaying when the
voltage is set through keypad.
The setting range: 0.0%~100.0%
Voltage increasing time is the time when the inverter
-69-
Function parameters
Default
Modify
value
10
30.00Hz
0
0
100.0%
5.0s

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive300-19 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents