INVT Goodrive300-19 Series Operation Manual page 56

Open loop vector inverter special for hoist
Table of Contents

Advertisement

Goodrive300-19 series open loop vector inverter special for hosit
Function
Name
code
Terminal
running
P01.18
protection
when
powering on
Action if
running
frequency<
P01.19
lower limit
frequency
(valid>0)
Hibernation
P01.20
restore
delay time
Detailed instruction of parameters
When the running commands are controlled by the
terminal, the system will detect the state of the
running terminal during powering on.
0: The terminal running command is invalid when
powering on. Even the running command is detected
to be valid during powering on, the inverter will not
run and the system keeps in the protection state until
the running command is canceled and enabled again.
1: The terminal running command is valid when
powering on. If the running command is detected to
be valid during powering on, the system will start the
inverter automatically after the initialization.
Note: This function should be selected with
cautions, or serious result may follow.
This function code determines the running state of the
inverter when the set frequency is lower than the
lower-limit one.
0: Run at the lower-limit frequency
1: Stop
2: Hibernation
The inverter will coast to stop when the set frequency
is lower than the lower-limit one. If the set frequency
is above the lower limit one again and it lasts for the
time set by P01.20, the inverter will restore to the
running state automatically.
This function code determines the hibernation delay
time. When the running frequency of the inverter is
lower than the lower limit one, the inverter will pause
to stand by.
When the set frequency is above the lower limit one
again and it lasts for the time set by P01.20, the
inverter will run automatically.
Note: The time is the total value when the set
-55-
Function parameters
Default
Modify
value
0
0
0.0s

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive300-19 Series and is the answer not in the manual?

Questions and answers

Table of Contents