INVT Goodrive300-19 Series Operation Manual page 158

Open loop vector inverter special for hoist
Table of Contents

Advertisement

Goodrive300-19 series open loop vector inverter special for hosit
Set value
Setting value 1 of Modbus
14
Setting value 2 of Modbus
15
16~21
Torque current (relative to the
22
rated current of the motor)
Exciting current (relative to
23
the rated current of the
24~30
Relative parameters list:
Function
Name
code
P06.00
HDO output
P06.14
AO1 output
P06.15
AO2 output
HDO
P06.16
high-speed
pulse output
Function
communication
communication
Reserved
motor)
Reserved
Detailed instruction of parameters
0: Open collector high-speed pulse output
1: Open collector output
0: Running frequency
1: Set frequency
2: Ramp reference frequency
3: Running rotation speed
4: Output current (relative to 2 times of rated current of the
inverter)
5: Output current (relative to 2 times of rated current of the
motor)
6: Output voltage
7: Output power
8: Set torque value
9: Output torque
10: AI1 input value
11: AI2 input value
12: AI3 input value
13: High-speed pulse HDI input value
14: Modbus communication set value 1
15: Modbus communication set value 2
-1000~1000, 1000 corresponds to 100.0%
-1000~1000, 1000 corresponds to 100.0%
0~2 times of the rated current of the motor
0~2 times of the rated current of the motor
-157-
Basic operation instruction
Instruction
Default
value
0
0
1
0

Hide quick links: