INVT Goodrive300-19 Series Operation Manual page 84

Open loop vector inverter special for hoist
Table of Contents

Advertisement

Goodrive300-19 series open loop vector inverter special for hosit
Function
Name
code
Shifting
sequence
P07.03
selection of
QUICK/JOG
commands
STOP/RST
P07.04
stop
function
Detailed instruction of parameters
2: Shift the display state by the shifting key. Press
QUICK/JOG to shift the displayed function code from
right to left.
3: Shift between forward rotations and reverse
rotations. Press QUICK/JOG to shift the direction of
the frequency commands. This function is only valid
in the keypad commands channels.
4: Clear UP/DOWN settings. Press QUICK/JOG to
clear the set value of UP/DOWN.
5: Coast to stop. Press QUICK/JOG to coast to stop.
6: Shift the reference manner of running commands.
Press QUICK/JOG to shift the reference manner of
running commands.
7: Quick commission mode (commission according to
the non-factory parameter)
Note: Press QUICK/JOG to shift between forward
rotation and reverse rotation, the inverter does
not remember the state after shifting during
powering off. The inverter will run in the running
direction set according to parameter P00.13
during next powering on.
When P07.02=6, set the shifting sequence of running
command channels.
0: Keypad control→ terminals control→
communication control
1: Keypad control←→terminals control
2: Keypad control←→communication control
3: Terminals control←→communication control
STOP/RST is valid for stop function. STOP/RST is
valid in any state for the fault reset.
0: Only valid for the keypad control
1: Both valid for keypad and terminals control
2: Both valid for keypad and communication control
-83-
Function parameters
Default
Modify
value
0
0