(rotation autotuning)
Note:
1. Set the motor parameters according to the name plate of the motor.
2. During the motor autotune, if rotation autotune is selected, de-couple the motor from the
load to make the motor in a static and empty state; otherwise, the result of autotune is
incorrect. The asynchronous motors can autotune the parameters of P02.06~P02.10.
3. During the motor autotune, if static autotune is selected, do not de-couple the motor from
the load. Because only some parameters of the motor are involved, the control performance is
not as better as the rotation autotune. The asynchronous motors can autotune the parameters
of P02.06~P02.10.
4. Motor autotune only involves the current motor. Switch the motor through P08.31 to carry
out the autotune on the other motor.
Relative parameters list:
Function
Name
code
P00.01
Running
P00.01=0 (keypad control)
Set autotuning method
Set P00.15=1
Press "RUN" key to enter
Detailed instruction of parameters
0: Keypad running command channel (LED off)
Ready
(P00.15)
into autotuning
In autotuning
Display"-END-"
Autotuning end
-139-
Basic operation instruction
Set P00.15=2
(static autotuning)
Default
value
1