INVT Goodrive300-19 Series Operation Manual page 85

Open loop vector inverter special for hoist
Table of Contents

Advertisement

Goodrive300-19 series open loop vector inverter special for hosit
Function
Name
code
Parameters
P07.05
state 1
Parameters
P07.06
state 2
Parameters
P07.07
for stopping
state
Detailed instruction of parameters
3: Valid for all control modes
0x0000~0xFFFF
BIT0: running frequency (Hz on)
BIT1: set frequency (Hz flickering)
BIT2: bus voltage (Hz on)
BIT3: output voltage (V on)
BIT4: output current (A on)
BIT5: running rotation speed (rpm on)
BIT6: output power (% on)
BIT7: output torque (% on)
BIT8~BIT9: reserved
BIT10: input terminals state
BIT11: output terminals state
BIT12: torque set value (% on)
BIT13~BIT14: reserved
BIT15: the current stage in multi-step speed
0x0000~0xFFFF
BIT0: AI1 (V on)
BIT1: AI2 (V on)
BIT2: AI3 (V on)
BIT3: HDI frequency
BIT4: motor overload percentage (% on)
BIT5: inverter overload percentage (% on)
BIT6: ramp frequency reference value (Hz on)
BIT7: linear speed
BIT8: AC inlet current (A on)
BIT9~15: reserved
0x0000~0xFFFF
BIT0: set frequency (Hz on, frequency flickering
slowly)
BIT1: bus voltage (V on)
BIT2: input terminals state
-84-
Function parameters
Default
Modify
value
0x03FF
0x0000
0x00FF

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodrive300-19 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Table of Contents