Goodrive300-19 series open loop vector inverter special for hosit
by the hierarchical reference of multi-step speed terminals. The mode supports up to 6 different
speed levels. The hierarchical contact can be connected to the selected digital input S terminal and
the corresponding speed reference is given by mulit-step speed hierarchical reference 1~5
(P19.06~P19.11). The mode does not need zero position detection or detect hierarchical joystick
fault.
The parameters of hierarchical remote control mode are as follows:
Function
code
P00.01
Running command channel
P00.06
A frequency command
P05.01
S1 terminal function selection
P05.02
S2 terminal function selection
P05.03
S3 terminal function selection
P05.04
S4 terminal function selection
P05.05
S5 terminal function selection
P05.06
S6 terminal function selection
P06.03
P06.04
P06.14
P06.15
Brake and contactor control
P19.01
7.16.6 Electromotion potentiometer mode
The wiring diagram of electromotion potentiometer mode is as follows:
Name
Relay RO1 output
Relay RO2 output
AO1 output
AO2 output
selection
Function
selection
Terminal
1
channel (LED flickering)
Hierarchical
13
reference
1
Forward rotation operation (FWD)
2
Reverse rotation operation (REV)
7
Fault reset (RET)
61
Hierarchical reference terminal 1
62
Hierarchical reference terminal 2
63
Hierarchical reference terminal 3
5
Fault output
34
Brake control output
0
Running frequency
5
Current output
0x01
Brake is controlled by inverter
-187-
Basic operation instruction
Function instruction
running
command
multi-step
speed
Need help?
Do you have a question about the Goodrive300-19 Series and is the answer not in the manual?
Questions and answers