2 Remove the tension from the inner flat belt pulleys by lifting up on
the stairarms, pulling the flat belts off the flat belt pulleys, and
then gently setting the stairarm down.
Gas Shock Removal
3 Release tension from the top of the gas shock by pushing a # 1 flat
top screw driver in the slot
completely remove the retaining clip as it is difficult to
reinstall.
Tip: If the incline motor is jammed at full elevation, remove the lower retaining
clip to facilitate the gas shock removal.
4 Using another flat head screw driver as a pry bar, place the screw
driver head between the frame and the top of the gas shock and pry
the shock off the upper mounting stud.
5 Rotate the gas shock down and out of the way of the incline motor.

Figure 324: Gas Shock

Disconnecting the Incline Motor
6 Remove the hitch pin from the Incline motor mounting pin.
7 Remove the Incline motor mounting pin. If the Incline is jammed or
has excessive pressure on the pin,
pin out of the Incline motor tube and Incline platform using a punch
and rubber mallet.
© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
under the tension clip. Do not
it may be necessary to drive the