Replacing The Lift Arm Housing; Lift Arm Housing Replacement Procedure; Figure 248: Generator - Precor AMT Series Service Manual

Table of Contents

Advertisement

28 Lift the stairarms and then thread the flat belts over the flat belt
pulleys.
29 Select the QUICKSTART program
resistance level 10 is displayed. Pedal the AMT for approximately
one minute, then recheck the belt tension.

Figure 248: Generator

30 The drive input belt tension should read approximately 180 ± 10 lbs
and the generator belt tension should read approximately 85 ±5 lbs.
Drive Belt Gauge Instructions
See
31 Lift the stairarms and thread the flat belts through the pulleys.
32 Replace the covers as per procedure,

Replacing the Lift Arm Housing

Lift Arm Housing Replacement Procedure

1 Remove the covers as per procedure,
2 Remove the tension from the inner flat belt pulleys by lifting up on
the stairarms, pulling the flat belts off the flat belt pulleys, and
then gently setting the stairarm down.
3 Loosen the two generator mounting bolts.
© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
and adjust the resistance  key until
(on page 142)
Cover Replacement
Cover Replacement
(on page 152).
(on page 152).