Poor Quality Video - Single Unit Only; Description; Possible Causes; Possible Remedies - Precor AMT Series Service Manual

Table of Contents

Advertisement

1 Turn the power off then back on. On treadmills, turn the on/off
switch to the off position then back to the on position. On self
powered units, disconnect the power source connected to the P80
console and then reconnect the power source.
2 Wait 15 seconds. It is critical that the timing be no less than 15
seconds and no greater than 45 seconds for the procedure to be
successful.
3 Repeat steps 1 and 2 for 6 additional power Off and On cycles.
4 On the last or 7
switch turned to the On position allowing the P80 console to boot up
completely.
5 If the P80 console boot up to the Welcome screen was successful, go
to step 6. If the P80 console still will not boot to the Welcome
screen contact PRECOR customer support.
6 Reprogram the P80 console with the most current software package
available. See Procedure 3.5, P80 Updating Software, for
instructions on how to reprogram the P80 console.

Poor Quality Video - Single Unit Only

Description

Television signal is present, but picture quality is consistently or
inconsistently poor across all available channels.

Possible Causes

1 Loose or damaged coaxial cable
2 Poor television signal to the machine
3 Incorrect region setting in channel settings

Possible Remedies

1 Check for good video signal to the tuner.
© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law