Figure 329: Incline Motor Mounting - Precor AMT Series Service Manual

Table of Contents

Advertisement

11 Remove the Incline motor 3/8-16 mounting bolt and remove the Incline
motor.

Figure 329: Incline Motor Mounting

Incline Motor Installation
12 Attach the replacement Incline motor to the frame using the
mounting bolt.
13 Connect the incline motor cable connector to the lower PCA and
replace the lower PCA cover as per procedure,
and Battery Bracket
14 Access the incline Lift Test portion of the Diagnostic Program, see
Accessing the P30 Diagnostic Software
51).
15 With the lift incline number displayed, set
using the STRIDE HEIGHT  and STRIDE HEIGHT  keys
16 Rotate the incline motor tube on the incline motor drive screw until
the measurement between the top of the incline nut and the end of
the incline motor drive screw is 1-1/4 inches.
Note: When rotating the incline motor tube, do not allow the incline
motor drive screw to rotate. If the incline motor drive screw rotates, the
lift level number will change. The lift level number must be 2 and the
physical measurement must be 1-1/4 inches for the calibration to be
correct.
© Precor Incorporated, Unauthorized Reproduction and Distribution Prohibited by Law
(on page 270).
(on page 13),
Replacing the Lower PCA
P80 Settings
(on page
the incline to level 2
Page 371

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amt 835Amt 885Amt 833Amt 823

Table of Contents