Figure 13: HR PCA Access Panel

4 The HR PCA snaps into its mounting. Press its tabs sideways and
remove the HR PCA from its mounting.
5 Disconnect the HR cable and handlebar cable from the HR PCA.
6
Connect the HHHR Grip cable assembly to the upper connector on the
HR PCA and the HR PCA Power cable to the lower connector on the
replacement HR PCA.
7 Orient the replacement HR PCA so that the side with the protective
foam pad is facing out and snap the HR PCA into its mounting.